Commercial

Over the years we have supplied security for many businesses and government agencies. We can accommodate your business no matter how big or small. 

Keeping your employees honest is another service we can provide by programming your system to record what time it is armed and disarmed and by which employee, as well as if employees come into your business after hours.  We can even notify you if your employees do not show up on time to open your business.

There are many options which we can customize to meet any of your business needs. If you would like to meet with us to discuss these possibilities please feel free to call us at (850) 243-1269 



 


 Vista 20-P Keypad
  • Viewable on system keypads: 
    – Exit countdown 
    – Time and date display
    – Event log
  • Auto keypad backlighting on entry
  • Keyswitch arming
  • Programmable macro buttons and single-button arming
  • Supports a variety of wireless remote controls for single-button operation
  • User Scheduling 
    – Automatically activates X-10 and relays at programmed times 
    – Latchkey reports to pagers 
    – Auto arm/disarm 
    – “User access” time windows
  • Supports up to four end-user numeric pagers
  • VIP Module allows system control from any touchtone phone
  • Chime by zone
  • Silent Panic Button
 

6271CV Touch Center 
 
  • Exit/Entry delay countdown
  • User codes: Allows authorized user to add or delete codes
  • View Zone Status: If system is not ready to arm, displays any open zones with:
    - Zone number
    - Zone description
    - Status
    - Authorized users may bypass and unbypass zones
  • Record and playback messages for users
  • Blinking LED indicates a message has been left
  • Over two minutes of recordable time
  • Track when workers and temporary guests use the system
  • Keep tabs on family members (e.g., checking if a child has armed the system upon returning home from school)
  • Utilize the TouchCenter as an effective business management tool (e.g., viewing openings and closings)
  • Emulation of standard 2x16 alpha LCD keypad display
  • Diagnostics allows testing of:
    - LCD display 
    - Audio
    - LED indicators
  • Silent panic button 
 


 6280 Touch Center
 
  • Exit/Entry delay countdown
  • User codes: Allows authorized user to add or delete codes
  • View Zone Status: If system is not ready to arm, displays any open zones with:
    - Zone number
    - Zone description
    - Status
    - Authorized users may bypass and unbypass zones
  • Record and playback messages for users
  • Blinking LED indicates a message has been left
  • Over two minutes of recordable time
  • Track when workers and temporary guests use the system
  • Keep tabs on family members (e.g., checking if a child has armed the system upon returning home from school)
  • Utilize the TouchCenter as an effective business management tool (e.g., viewing openings and closings)
  • Emulation of standard 2x16 alpha LCD keypad display
  • Diagnostics allows testing of:
    - LCD display 
    - Audio
    - LED indicator
  • Silent Panic Button

 Lynx Touch
 
  • 4.7 inch color graphic touchscreen 
    - Resolution 470 x 256 pixels 
    - 16.7 million colors 
    - Intuitive easy-to-use touchscreen interface 
    - Easy to understand icons 
    - Menu driven navigation 
    - Quick accurate programming 
    - Four dedicated keys for everyday functions
  • Works with Total Connect 2.0 - Event notification is easy to set and is changeable by the user
  • Voice announcement of system and zone status
  • Family message center (for user recorded messages)
  • Energy savings—with the optional Z-Wave® Bridge, LYNX Touch can set back Z-Wave thermostats based upon arming away or disarming
  • Voice chime by zone
  • Automatic stay arming
  • Remote phone control
  • Speaker phone operation
  • 16 programmable reminders
  • “Follow me” reminder and system announcements; users can be notified by phone of reminders and system events. Supports two end-user phone numbers.
  • 16 user codes (Installer, Master, Babysitter, Duress, 14 Secondary)
  • Three panic functions
  • Wall or desk mount
  • Viewable event log stores up to 128 events
  • Case tamper
  • Exit error feature (detects difference between an actual alarm and exit alarm caused by leaving a door open after the exit delay expires)
  • RF jam detection
  • Quick Exit feature enables users to leave the premises for a brief time without disarming system
  • Hinged cover for easy installation
  • Real-time clock display
  • Silent Panic Button 
 
 


 Motion Detectors
 A passive infrared motion detector (PIR) is an electronic security device that detects intruders by "sensing" motion or body heat in the area being protected. Most PIRs are designed to be used when your family is away from home or when no one will be passing through the area "covered" by the PIR.
 

 Indoor/ Outdoor Video
 Wired/Wireless IP Cameras feature a compact, portable design—allowing you to move them whenever you choose. A pan/tilt version is also available. WAP (Wireless Access Point) provides secure, wireless networking ability (Wi-Fi) in iPCAM installations. It connects easily to a port on a router and is configured with iPCAMs using Wi-Fi Protected Setup (WPS).

Total Connect Remote Video Services, part of the suite of Total Connect digital communications services, lets end-users view activity around the interior or exterior of their homes or businesses on PCs or mobile devices over a highly secure Internet connection.


Silent Panic Switch
................................................... 

The Panic button is an initiating device that is used in a panic system, and located (concealed) under counters, under desktops, and inside walk-in freezers. When a user activates the Panic button, it sends a data message to the system control panel for processing. When the Panic/Holdup button is reset, it sends a data message to the panel, indicating that it is in a normal condition. Users see status and alarms from the sensor at the local keypad. The control panel can also send a message to the monitoring station.

 
 ....................................................................................................



 